Filter Results By:

Products

Applications

Manufacturers

Impulse Test

Check using a short surge of energy.


Showing results: 76 - 90 of 97 items found.

  • AC Insulation Testing

    Weshine Electric Manufacturing Co., Ltd

    High-voltage Dividers (High Potential Divider) are used to measure voltages and decouple partial discharges in high-voltage test systems. Depending on the specific type, they are used to measure alternating voltage (AC), direct voltage (DC), lightning impulse voltage (LI), and switching impulse voltage (SI) systems. High-voltage dividers by HIGHVOLT comply with the relevant IEC standards. The systems are available for both indoor and outdoor use.

  • Impulse Winding Tester

    DWX Series - ECG KOKUSAI Co., Ltd.

    The DWX tester is designed to test other coils and low inductance coils used in high-end electronic components. Through the use of impulse power source with high-speed switch, highly efficient input circuit, and high-speed A/D sampling circuit, the DWX tester can offer a new solution to the low inductance coil tests.

  • AUTOMATIC WINDING TEST SYSTEM

    VE9036SU - Vasavi Electronics

    6 CHANNEL Microprocessor based Automatic Test System for Automobile Coils, Magnetos, Alternator, Motor Winding. Can Test : Impulse Winding Tester (IW), AC/DC HiPot, Insulation Resistance (IR), Inductance (L), DC Resistance (DCR)

  • Current Tester

    MIG0624 - EMC Partner AG

    The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.

  • Clamping Voltage Tester

    MIG0603CLV1 - EMC Partner AG

    The MIG0603CLV1 is a generator for testing varistors. It has circuits with three different source impedances and up to 11 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 200A which is maintained over the entire load range.

  • Impulse Semiconductor High Current Integrated

    Transmission Line Pulse Test System - Impulse Semiconductor Inc.

    The Impulse Semiconductor High Current Transmission Line Pulse (TLP) test system is the tool of choice for extracting ESD parameters for transient protection devices in a package, or at wafer level. With accuracy better than 100 milliohms at 40 amps peak current, the Impulse high current TLP is specially tailored to the needs of today's ESD device designers who must accurately measure low values dynamic resistance irrespective of breakdown voltage.

  • Clamping Voltage Tester

    MIG0603CLV2 - EMC Partner AG

    The MIG0603CLV2 is a generator for clamping voltage testing of varistors. It has circuits with four different source impedances and up to 15 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 500A which is maintained over the entire load range.

  • Wound Component EST Analyzer

    19036 - Chroma Systems Solutions, Inc.

    The industry’s first Wound Component Electrical Safety Test (EST) Analyzer that combines impulse winding, AC/DC hipot, insulation resistance and DC resistance test measurement functions. Chroma’s 19036 Wound Component EST Analyzer has 5kVac/ 6kVdc high voltage output, 5kV insulation resistance, 6kV layer short impulse voltage and 4-wire DC resistance measurement with a maximum output of up to 40 channels. Capable of outputting and measuring AC100mA/DC 20mA, Chroma’s 19036 is suitable for testing to high power motor standards such as UL 1004-1.

  • Audio Test Tone Generator

    ToneGenerator - NCH Software Pty Ltd

    Tone Generator is a sine wave generator, frequency generator and signal generator that lets you create audio test tones, sweeps or noise waveforms using your computer or a PDA handheld. Generate sine wave, square wave, triangular waveform, saw tooth waveform, impulse, white noise and pink noise.

  • Flammability Test System

    COMP0804CAP - EMC Partner AG

    Active flammability test system according to IEC 60384-14 Ed4. For testing X & Ycapacitors up to 1uF. The test system includes control of the nominal AC supply via an integrated variac up to 1800V. Impulse amplitudes are programmable up to 8kV which covers all requirements. X1 capacitors are stressed up to 4kV, X2 and Y4 capacitors up to 2.5kV and Y2 capacitors up to 5kV.

  • Qualification and Quality Control Tests

    Techsquare - Techimp HQ S.r.L

    New IEC standards, IEC 60034-18-41 and IEC 60034-18-42, have been issued to define the procedures for testing partial discharge inception voltage and the long-term performance (endurance) of Type I and Type II insulation systems used in rotating machines fed from voltage converters. Voltage impulse generators are required at least to test turn insulation, but they would be recommended for any testing under power electronics supply because of their capability to simulate the real electrical stress conditions. More generally, any type of electrical insulation system when subject to impulsive voltage waveform during life should be carefully evaluated in terms of partial discharge and endurance behaviour. This is why voltage impulse generators able to provide impulses with controlled amplitude and frequency are needed to face this new testing challenge.

  • ITSM Synchro

    Techimp HQ S.r.L

    The Impulsive Test Synchronization Module (ITSM) is a device aimed at generating a digital synchronization signal, to use the PDBaseII system for impulsive voltage PD test. The digital synchronization signal generated by the ITSM, is synchronized with the voltage impulse of the impulsive source (voltage generator). The ITSM must be connected between the DIN channel of PDBaseII and the output of the synchronization sensor (e.g. capacitive coupler). The ITSM provides also a low voltage signal reproducing the impulsive voltage source.

  • HV Coupling Capacitors

    Mess- & Prüfsysteme GmbH

    Our high-voltage coupling capacitors are a main component of our partial discharge test stations. They serve to decouple the partial discharge impulses and act as a voltage divider, the output voltage of which is matched to our partial discharge measuring devices (with integrated voltage measurement) and peak voltage measuring devices. These high-voltage components are also available separately in their various designs, sizes, capacities and voltage ranges.

  • Power Frequency Transducer

    PP1S - Hsiang Cheng Electric Corp

    1. Measuring and conversion IEC 6882. Dielectrical strength IEC 688 4 KVac / 1 min.3. Impulse test ANSI C37.90 / 1989 IEC 255-3 5KV ( 1.2 x 50 us ) 3KA ( 8 x 20 us ) - current coil4. Surge test (ring wave) ANSI C37.90 / 1989 ( 3KV - 0.5us / 100KHz ) IEC 255-3 ( 2.5KV - 0.25ms / 1MHz )5. Adaptability for power system VDE 0110 6. Measuring reliability VDE 3540

  • Digital Surge Tester

    KT-905D - Kast Eng Co. LTD.

    Surge Tester of KAST is divided for the use of 3¡­40 §Ç by output voltage, and subdivided into type C of manual decision type, type A of auto decision type, type L of exclusive use for low inductance product test and type P loading printer which can printout its wave form and digital scope. Surge test requires only 0.5 second. Because Surge tester already performs 30 times of Impulse voltage test only for 0.5 second. Turn-to-turn short : phenomenon shorted between the side coils. 